A Sensitive Ultrahigh-Performance Liquid Chromatography/Tandem Mass Spectrometry Method for the Simultaneous Analysis of Phytocannabinoids and Endocannabinoids in Plasma and Brain

Faizy Ahmed, Alexa Torrens, Stephen V Mahler, Francesca Ferlenghi, Marilyn A Huestis, Daniele Piomelli. Cannabis Cannabinoid Res. 2024 Feb;9(1):371-385.

Laboratory studyOther animals

Design
Laboratory study
Subjects
Method validation, with an application in adolescent male and female mice
Dose used in the study
No palmitoylethanolamide was given; PEA was one of the measured analytes
Duration
Not stated in the abstract
What was measured
Simultaneous quantification of THC, its metabolites, CBD, anandamide, 2-AG, PEA and OEA in plasma and brain by UHPLC/MS-MS; linearity, limits of quantification and detection.

What the authors reported

Calibration was linear (R2 > 0.99) from 0.02 to 500 ng/mL. The lowest limit of quantification for PEA was 2.0 ng/mL and the detection limit 1.0 ng/mL. Applying the method showed that phytocannabinoid administration raised endocannabinoid levels in plasma and brain of adolescent mice.

Limits of this study

An analytical-method paper with a mouse application; it cannot show effect in people. The authors declare no competing interests.